Precision Planetary Reducer
Classification :
Precision Planetary Reducer
Keywords :
Precision Planetary Reducer
Download :
Products
Speed Reducer Selection Guide
The selection of reducer should be examined for its structure type, installation form, load-bearing capacity, output speed, working conditions and other factors. Determination of reducer sample specifications: The load-bearing capacity of the reducer is derived under the conditions of rated speed, working less than 12 hours per day, starting less than 10 times per hour, and flat without impact. If there are different use cases should be selected according to the following steps.
(一)Check the selected configuration
The use factor f is determined by the type of load, the number of starts and stops per hour and the expected working life
| Usage factor (fs) | ||||||
| Load Type | Number of starts per hour Z | Daily running time (h) | ||||
| h<4 | 4<h<8 | 8<h<12 | 12<h<16 | 16<h<24 | ||
| Uniform load | Z<10 | 0.85 | 0.95 | 1.00 | 1.20 | 1.60 |
| 10<Z<30 | 0.90 | 1.10 | 1.15 | 1.40 | 1.80 | |
| 30<Z<100 | 1.00 | 1.20 | 1.30 | 1.60 | 2.00 | |
| Medium load | Z<10 | 1.00 | 1.20 | 1.30 | 1.60 | 2.00 |
| 10<Z<30 | 1.10 | 1.35 | 1.45 | 1.80 | 2.20 | |
| 30<Z<100 | 1.20 | 1.45 | 1.60 | 2.00 | 2.40 | |
| Heavy load | Z<10 | 1.20 | 1.45 | 1.60 | 2.00 | 2.40 |
| 10<Z<30 | 1.30 | 1.55 | 1.75 | 2.20 | 2.60 | |
| 30<Z<100 | 1.40 | 1.65 | 1.90 | 2.40 | 2.80 | |
The safety factor can be selected according to the following table
|
Usage requirements |
Minimum safety factor |
| High reliability | 1.50~1.60 |
| High reliability | 1.25~1.30 |
| General Reliability | 1.00~1.10 |
1. Maximum torque
Confirm that the instantaneous peak load torque and starting torque with load cannot exceed the rated maximum torque T of the reducer. The specific parameter values are listed in the reducer rating table.
2.Cantilever load
Mainly for cantilevered rack and pinion, timing belt pulley, etc. need to carry large radial force or axial force. Selection of swing, in accordance with a certain speed and the force point in the shaft extension a 1/2 consider, require Cao inter need radial force or axial force is less than the standard value of the sample (pay attention to the speed of rotation value. The lower the rotational speed, the relative bearing radial force will improve the force paste farther away from the shoulder of the shaft, the bearing radial force will decline). If with special circumstances, you can contact with our engineering staff.
-
- Precision Planetary Reducer
RELATED PRODUCTS
Feedback